# HMI icons

[Home](/articles/clean-power-vfd-publication/home) » [Smart HMI](/articles/clean-power-vfd-publication/smart-hmi) » HMI icons

* * *

The Clean Power VFD HMI uses icons to identify available actions, menu functions, configuration options, and the current operating state of the drive.

Some icons are interactive and can be tapped to perform an action. Other icons are indicators only and change automatically according to the state of the drive, motor, PID controller, communication interface, or I/O.

The appearance of an icon may also change according to its state. For example, an icon may be dimmed when a function is unavailable, highlighted when selected, or replaced by another icon when the state changes.

**Note:** An icon does not replace the information displayed with it. When an alarm, warning, or safety message is displayed, always follow the accompanying message.

* [Common action icons](/articles/clean-power-vfd-publication/hmi-icons/a/h2__455166709)
* [Navigation icons](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1578384066)
* [Selection and input controls](/articles/clean-power-vfd-publication/hmi-icons/a/h2_625942017)
* [Drive and motor status icons](/articles/clean-power-vfd-publication/hmi-icons/a/h1__1696616554)
* [Motor operating state](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1239943373)
* [Local and remote control](/articles/clean-power-vfd-publication/hmi-icons/a/h2__337705831)
* [PID operating status](/articles/clean-power-vfd-publication/hmi-icons/a/h1_290539798)
* [Alarm and warning indicators](/articles/clean-power-vfd-publication/hmi-icons/a/h1__1823949356)
* [I/O status indicators](/articles/clean-power-vfd-publication/hmi-icons/a/h1_387846995)
* [Limit indicators](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1625592723)
* [Communication and pairing indicators](/articles/clean-power-vfd-publication/hmi-icons/a/h1__476352925)
* [Bluetooth signal strength](/articles/clean-power-vfd-publication/hmi-icons/a/h3__4211059)
* [Configuration and menu icons](/articles/clean-power-vfd-publication/hmi-icons/a/h1__805978106)
* [Alarms and monitoring](/articles/clean-power-vfd-publication/hmi-icons/a/h2_111598911)
* [Motor control](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1997134642)
* [Remote control and communication](/articles/clean-power-vfd-publication/hmi-icons/a/h2_2090174984)
* [System, hardware, and display](/articles/clean-power-vfd-publication/hmi-icons/a/h2__1241399406)
* [Configuration management](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1347549219)
* [Other functions](/articles/clean-power-vfd-publication/hmi-icons/a/h2__327168439)
* [I/O function icons](/articles/clean-power-vfd-publication/hmi-icons/a/h1__1586873853)
* [Progress indicators](/articles/clean-power-vfd-publication/hmi-icons/a/h1__2094058777)
* [Icons that change according to context](/articles/clean-power-vfd-publication/hmi-icons/a/h2_1648660099)

* * *

##  Common action icons

| Icon | Meaning |
| --- | --- |
| **![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07.png)** | Opens the alarms. On the Dashboard, a badge on the bell shows the number of alarms. The same symbol is also used to access alarm settings. |
| **![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-1.png)** | Indicates that configuration changes are waiting to be saved or applied. Tap the icon to save the changes. When there are no pending changes, the icon is replaced by the **Close** icon. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-2.png) | Deletes the selected item, such as a configuration profile, ramp curve, ramp segment, or setpoint preset. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-3.png) | Indicates that additional options or modes are available. Tap the icon to display the available choices. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-4.png) | Opens contextual help. From the **About** menu, the Help entry provides access to the drive documentation. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-5.png) | Displays additional information about a setting. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-6.png) | Decreases the selected motor setpoint by one step. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-7.png) | Increases the selected setpoint by one step or adds a new item to a configurable list. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-8.png) | Indicates that the displayed value can be edited. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-9.png) | Clears the value currently entered in an editable field. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-10.png) | Closes the current screen, dialog, or editor without navigating further. On configuration screens, it is replaced by the Save icon when unsaved changes exist. |

**Editable and unavailable values**

A **Pencil ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-8.png)**icon identifies a value that can be modified.

A crossed-out or dimmed **Pencil** indicates that the value cannot currently be edited. The availability of editing may depend on the operating mode, control source, drive state, or configuration.

* * *

## Navigation icons

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-11.png) | Returns to the previous screen or selects the previous item, preset, card, or month. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-12.png) | Opens the selected menu item or moves to the next item, preset, card, or month. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-13.png) | Identifies the main menu. The Menu icon in the Dashboard footer opens the main menu. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-14.png) | May also appear in the Main Menu title bar as a visual identifier. In this location it is not an active button. |

On menu screens, a **right chevron** at the end of a row indicates that tapping the row opens another screen.

* * *

## Selection and input controls

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-15.png) | Deletes the last digit entered using the numeric keypad. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-16.png) | Indicates an unselected option or a step that has not yet started. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-17.png) | The option is not selected. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-18.png) | The selection or operation is pending or being applied. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-19.png) | The option has been selected or confirmed. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-20.png) | Shows a password or PIN that is currently hidden. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-21.png) | Hides a password or PIN that is currently visible. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-22.png) | The option is not selected. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-23.png) | The option is selected. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-24.png) | The function or setting is enabled. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-25.png) | The function or setting is disabled. |

* * *

## Drive and motor status icons

The Dashboard uses status icons to show the current operating state of the Clean Power VFD and motor. These indicators can change automatically as the operating state changes.

### Motor operating state

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-27.png) | Starting — a Start command has been accepted and the drive is preparing to run the motor. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-28.png) | Magnetizing — the drive is magnetizing the motor before rotation begins. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-29.png) | Ramping up — the motor is accelerating toward its commanded setpoint. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-31.png) | The motor is commanded or operating in the forward direction. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-32.png) | The motor is commanded or operating in the reverse direction. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-30.png) | Ramping down — the motor is decelerating. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-35.png) | The motor is stopped. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-33.png) | The motor is paused. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-34.png) | The motor is disabled and cannot run. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-36.png) | Motor autotuning is in progress. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-37.png) | The drive state or direction cannot be represented by one of the normal status icons. This is a fallback indication and should rarely be displayed. |

The Forward and Reverse icons may also appear in configuration screens when assigning Forward or Reverse functions to digital inputs.

* * *

## Local and remote control

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-1.jpg) ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/localControl_black_on_white.svg) | The Clean Power VFD is being controlled locally from the HMI. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/remoteControl_black_on_white.svg) | The Clean Power VFD is being controlled from a remote source, such as the control terminals, or communication protocol. |

Always verify the active control source before attempting to operate the motor.

* * *

## PID operating status

When PID control is active, the HMI uses additional icons to identify the current PID state.

| Icon | Meaning |
| --- | --- |
| ![trending up](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-29.png) | The PID controller is increasing its output or commanding the motor in the forward direction. |
| ![trending down](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-30.png) | The PID controller is reducing its output or stopping. |
| ![trending neutral](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-38.png) | The PID controller is maintaining a constant output. |
| ![arrow expand vertical](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-39.png) | **Deadband** — the process value is sufficiently close to the setpoint that no correction is currently required. |
| ![Sleep](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-41.png) | **Sleep** — the PID controller has placed the drive in Sleep mode because motor operation is not currently required. |
| ![Bell Sleep](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-40.png) | **Going to sleep** — the PID controller is preparing to enter Sleep mode. |
| ![Alarm clock](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-42.png) | **Waking up** — the PID controller is leaving Sleep mode and preparing to resume operation. |
| ![wrench](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-43.png) | **Forced output** — PID output is being forced to a configured value rather than being calculated normally by the PID loop. |
| ![Lock](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-44.png) | PID control is inactive because the motor is disabled. |
| ![stop](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-35.png) | PID control is stopped or inactive. |

* * *

## Alarm and warning indicators

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08.png) | Indicates an alarm or an important safety-related message. In the alarm list, its color reflects the alarm severity. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-1.png) | Indicates an error or problem associated with a setting, operation, or process step. When available, tap the associated item to view more information. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-2.png) | Indicates a warning associated with a configuration or operating condition. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-3.png) | Identifies active alarms or an alarm condition requiring acknowledgement. For relays it marks the output that activates when an alarm needs acknowledgement. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-4.png) | All active alarms are acknowledged. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-5.png) | Identifies the command used to reset eligible alarms or faults. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-7.png) | Identifies an alarm-related relay function, such as activation for a non-minor alarm. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-8.png) | Identifies external alarm configuration. |

Alarm and warning icons draw attention to a condition but do not, by themselves, describe its cause. Refer to the alarm text displayed on the HMI for the specific condition and required action.

* * *

## I/O status indicators

The **Diagnostics &gt; I/Os status** screens use icons to identify the configuration and actual state of the drive inputs and outputs.

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-9.png) | The digital input or output is active. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-10.png) | The digital input or output is inactive. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-11.png) | The input or output is not configured. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/speedometer.svg) | The corresponding I/O or value is unavailable. |

* * *

## Limit indicators

Current and power limit screens use colored indicators to show whether a configured limit is actively restricting operation.

| Indicator | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-16.png) | The limit is configured but is **not currently active**. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-17.png) | The limit is **currently active** and is restricting motor operation. |

* * *

## Communication and pairing indicators

| Icon | Meaning |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-18.png) | Identifies Bluetooth Low Energy functions or BLE pairing. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-19.png) | Bluetooth is disabled and BLE pairing is unavailable. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-20.png) | Identifies Wi-Fi as the selected mobile-device pairing method. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-21.png) | Opens or identifies mobile-app installation and pairing using a QR code. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-22.png) | Indicates that a mobile device can be paired. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-23.png) | Mobile-device pairing completed successfully. |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-24.png) | Mobile-device pairing failed. |

### Bluetooth signal strength

The connected-device screen uses signal bars to indicate Bluetooth signal strength.

| Icon | Approximate signal level |
| --- | --- |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-25.png) | Extremely weak — below approximately −100 dBm |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-26.png) | Weak — approximately −100 to −70 dBm |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-27.png) | Medium — approximately −70 to −55 dBm |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-28.png) | Strong — stronger than approximately −55 dBm |

* * *

## Configuration and menu icons

The following icons help identify functions in the HMI menus. The text displayed beside the icon remains the primary identification of the function.

## Alarms and monitoring

| Icon | Function |
| --- | --- |
| ![Bell](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-12.png) | Alarms |
| ![Bell with exclamation mark](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-3.png) | View alarms |
| ![Bell with check mark](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-4.png) | Acknowledge all alarms |
| ![Bell with minus](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-5.png) | Reset alarms |
| ![Bell with plus](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-8.png) | External alarm settings |
| ![ringing bell](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-7.png) | Alarm-related relay function |
| ![heartbeat line](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-13.png) | Live diagnostic measurements, including the power meter and fan diagnostics |

* * *

## Motor control

| Icon | Function |
| --- | --- |
| ![two cogs](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09.png) | Motor control, motor monitoring, or motor metrics |
| ![cog with transfer arrows](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-1.png) | Motor tuning, limits, Static Autotuning, or Dynamic Autotuning |
| ![chart line](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-2.png) | Acceleration and deceleration ramp curves |
| ![cumulative chart curve](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-3.png) | Motor load curve |
| ![thermometer](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-4.png) | Motor thermal protection |
| ![slow speedometer](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-5.png) | Frequency/velocity reference or Torque boost |
| ![speedometer](/resources/Storage/clean-power-vfd-publication/hmi-icons/speedometer.svg) | Motor frequency, velocity, torque, or related output function |
| ![restart](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-6.png) | Motor Auto Restart |
| ![horizontal swap arrows](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-7.png) | Automatic switchover between configured limits |
| ![target](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-8.png) | Selection of the motor speed or velocity reference |
| ![sine wave](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-9.png) | AC line information, motor current, or drive power |
| ![PID](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-10.png) | PID process control settings |

* * *

## Remote control and communication

| Icon | Function |
| --- | --- |
| ![network](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-11.png) | Remote control or communication settings |
| ![cog](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-12.png) | Common remote-control settings |
| ![gamepad](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-13.png) | Modbus/TCP |
| ![hexagon outline](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-14.png) | BACnet |
| ![IP network](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-15.png) | EtherNet/IP |
| ![CellPhone](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-16.png) | Mobile control |
| ![LAN connected](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-17.png) | Network status and configuration |
| ![LAN setting](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-18.png) | Network settings |
| ![access point](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-19.png) | Ping / network reachability settings |

* * *

## System, hardware, and display

| Icon | Function |
| --- | --- |
| ![Computer](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-20.png) | System, controller, configuration, or VFD metrics |
| ![Clock](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-21.png) | Date, time, and timezone |
| ![display screen](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-22.png) | Display settings, display information, or display diagnostics |
| ![display with padlock](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-23.png) | Display locking |
| ![chip](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-24.png) | Hardware information |
| ![code tags](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-25.png) | Software information |
| ![information](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-26.png) | General product, software, hardware, or motor information |
| ![Glasses](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-27.png) | Diagnostics |
| ![color palette](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-28.png) | Display color test |
| ![tap gesture](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-29.png) | Touchscreen test |
| ![fan](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-30.png) | Cooling-system diagnostics |

* * *

## Configuration management

| Icon | Function |
| --- | --- |
| ![backup restore](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-31.png) | Restore the factory-default configuration |
| ![download](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-33.png) | Export configuration to USB |
| ![upload](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-34.png) | Import configuration from USB |
| ![file swap](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-35.png) | Configuration profiles |
| ![folder download](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-37.png) | Export a support package or audit logs |
| ![download](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-38.png) | Software update |
| **[USB drive]** | Software update from a USB drive |

* * *

## Other functions

| Icon | Function |
| --- | --- |
| ![wizard hat](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13.png) | Quick setup |
| ![Hammer and wrench](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-1.png) | Maintenance mode |
| ![Flame](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-2.png) | Fire/Emergency Mode configuration or the digital input assigned to Fire/Emergency Mode |
| ![air damper](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-3.png) | Damper control |
| ![connector](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-4.png) | I/O configuration |
| ![digital signal](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-5.png) | I/O status |
| ![QR code](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-6.png) | Mobile-app setup |

* * *

## I/O function icons

When configuring the inputs and outputs of the Clean Power VFD, icons are displayed beside some selectable functions to make them easier to identify.

| Icon | I/O function |
| --- | --- |
| ![network with X](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-7.png) | No specific I/O function icon is assigned, or the function is unassigned. |
| ![Cog with synchronization arrows](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-8.png) | Select active configuration |
| ![engine](/resources/Storage/clean-power-vfd-publication/hmi-icons/electric-motor.svg) | Motor running relay |
| ![engine off](/resources/Storage/clean-power-vfd-publication/hmi-icons/electric-motor-off.svg) | Motor lockout relay |
| ![pointing hand](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-11.png) | Select PID forced-output state |
| ![damper](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-3.png) | Damper feedback |
| ![chain link](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-12.png) | Select control mode or remote-control source |
| ![lock reset](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-13.png) | Reset lockout |
| ![blocked circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-14.png) | Interlock |
| ![progress check](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-15.png) | Motor ready to run |
| ![chart sankey](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-16.png) | Select ramp-up or ramp-down curve |
| ![swap arrows in a circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-17.png) | Relay indication for automatic switchover |
| ![clockwise direction](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-18.png) | Forward Run input |
| ![counter clockwise direction](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-19.png) | Reverse Run input |
| ![stop](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-35.fr-CA.png) | 3-wire Stop input |
| ![alarm clock](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-42.png) | External alarm input |
| ![fire](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-2.png) | Fire/Emergency Mode input |
| ![](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-1.png) | Maintenance Mode input |
| ![target](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-09-8.png) | Select frequency or velocity reference |

* * *

## Progress indicators

Several HMI procedures, including software update and motor autotuning, use step indicators.

| Icon | Meaning |
| --- | --- |
| ![empty circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-07-16.png) | The step has not started. |
| ![filled circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-20.png) | The step is current or has been reached. |
| ![check in circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-08-23.png) | The step or selection is complete. |
| ![circulator arrows](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-21.png) | The operation is currently in progress. |
| ![exclamation mark in a circle](/resources/Storage/clean-power-vfd-publication/hmi-icons/hmi-icons-2026-10-13-22.png) | An error occurred during the step. |

The circular-arrows icon may rotate while an operation is in progress.

* * *

## Icons that change according to context

Some HMI icons have more than one function depending on where they are displayed.

For example:

* **Plus** and **Minus** change the setpoint during direct setpoint adjustment.
* In preset-selection mode, they are replaced by **left** and **right chevrons** to select another preset.
* The **Pencil** changes to a crossed-out Pencil when editing is unavailable.
* The **Close** icon changes to **Save** when configuration changes are waiting to be applied.
* Digital I/O icons change according to whether the signal is active or inactive.
* Dashboard status icons change automatically as the motor moves through Starting, Magnetizing, Ramping, Running, Stopping, and Stopped states.
* PID icons change as the controller enters states such as Deadband, Sleep, Waking up, or Forced output.

These changes provide immediate visual feedback about the current state of the Clean Power VFD.